Sign In | Join Free | My fnxradio.com
China Guangzhou rongan fire equipment co. LTD logo
Guangzhou rongan fire equipment co. LTD
Guangzhou rongan fire equipment co. LTD
Verified Supplier

2 Years

Home > IG541 Fire Suppression System >

15MPa IG541 Inert Gas Fire Suppression System For Communication Facilities

Guangzhou rongan fire equipment co. LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

15MPa IG541 Inert Gas Fire Suppression System For Communication Facilities

  • 1
  • 2
  • 3

Brand Name : Rongxiao

Model Number : 90L

Certification : CAL,CMA,CNAS,,CCC

Place of Origin : Guangzhou City, Guangdong Province, China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C, D/P, Western Union, T/T, Credit card

Supply Ability : 18000 sets per week

Delivery Time : 10 days, subject to quantity negotiation

Packaging Details : Plywood outer box with bubble bag or paper

Capacity Of Cylinder : 70L,80L,82L,90L

Extinguishing Method : Chemical Reaction

Temperature Range : 0°C to 50°C

Trademark : Rongan

Storage Pressure : 15Mpa/20MPa

Activation Time : 37 Seconds

Contact Now

15MPa IG541 Inert Gas Fire Suppression System For Communication Facilities

Product Introduction

IG541 fire extinguishing system is a new type of gas fire extinguishing system developed in recent years. It is one of the ideal alternatives to halon fire extinguishing system.

IG541 is a widely available and non-corrosive gas that neither supports combustion nor reacts with most substances. The fire extinguishing agent contains only three natural gases: 52% ammonia, 40% xenon, and 8% carbon dioxide. The summer oxygen depletion potential (ODP) value is zero, and it will not have a greenhouse effect on the earth.

IG541, as an effective fire extinguishing agent, has many excellent properties: non-corrosive, non-destructive, no adverse decomposition products, no residue left after extinguishing the fire, and non-conductive, so it can be used in electrical fire hazards. It can be sprayed through pipes and nozzles with its own pressure, and can penetrate and diffuse to all parts of the dangerous area; it is easy to obtain and the price is lower than other fire extinguishing systems.

When IG541 fire extinguishing agent is sprayed into the protection area, the air in the area is connected with a gas mixture that meets the design concentration range. Its release causes the oxygen concentration in the area to peak below 15% and extinguish the fire, while the carbon dioxide concentration rises to 4%. The increase in carbon dioxide concentration speeds up people's breathing rate and ability to absorb oxygen, so that people's breathing is not affected in a hydrogen-deficient environment, and there is no suffocation hazard to the human body.

System technical parameters and composition

System technical parameters

Executive standard GB 25972-2010
System working pressure(20℃时,MPa) 15 20
Volume of fire extinguishing agent bottle group(L) 70 80 90 80 82 90
System injection time(s) ≤60 ≤60
Filling quantity of extinguishing agent(kg) 14.77 16.88 18.99 22.49 23.05 25.3
System service temperature(℃) 0~+50 0~+50
Minimum fire extinguishing design concentration 37.5% 37.5%
Safe design concentration of manned workplace ≤43% ≤43%

Company introduction:

Guangzhou Rongan Fire Protection Equipment Co., Ltd. is a professional manufacturer of fire protection facilities integrating R&D, production, design and sales services. The company has experts from the national fire protection industry standards committee and a group of professional technical service teams with more than ten years of experience in the fire protection industry, and will spare no effort to provide you with the most intimate and professional comprehensive technical solutions for fire protection engineering products. "Rongxiao" series products produced by the company have passed the national compulsory product certification and the national fixed fire extinguishing system inspection center, with reliable quality and stable performance, and the factory has passed the ISO9001 quality system certification.

Frequently asked questions:

Q1: Are you a manufacturer or a trading company? A1: We are manufacturers.

Q2: How long is the delivery time? A2:10 days, which can be negotiated according to the quantity.

Q3: How to deal with the fault? A3: During the warranty period, we will provide you with a remote emergency plan during working hours. During the free maintenance period, the company will replace spare parts or complete machines that have failed due to defects or quality problems free of charge.


Product Tags:

15MPa IG541 Fire Suppression System

      

Communication Facilities Fire Suppression System

      

15MPa Fire Suppression System

      
Wholesale 15MPa IG541 Inert Gas Fire Suppression System For Communication Facilities from china suppliers

15MPa IG541 Inert Gas Fire Suppression System For Communication Facilities Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou rongan fire equipment co. LTD
*Subject:
*Message:
Characters Remaining: (0/3000)